        The hunt chain
        Other required settings
Basic hardware configurations
The basic hardware required to run Voice Services is a Connected Systems PBXLink and one or more Brooktrout TR114 4L ISA or PCI cards. This booklet explains how to install these cards, and configure them to be used with a Nortel Meridian 1 PBX. Throughout the installation process, you should keep track of all settings on a worksheet modelled on the one found at the end of this booklet.
Brooktrout card
The Brooktrout card connects four analog phone lines to the PBX. These are the lines the actual call is transferred to in order to be processed by Voice Services. Only the pilot number is ever dialed directly. (This is how users log in.)
Each Brooktrout card has four blinking red lights (corresponding to the 4 lines). When a port is busy, the corresponding red light will be lit solidly for the duration of the call. When the caller hangs up, the light will begin to blink again. If there are no lights lit on the card, the card or the lines may be malfunctioning or the machine may have lost power.
The more Brooktrout cards you have (more users, more lines), the more available slots you will require on the Voice Services machine. For information on the number of ports required for your system, see the recommendations here.
Connected Systems PBXLink
All references to Connected Systems PBXLink in this section pertain to both the Connected Systems PBXLink ISA 4x4 and the Connected Systems PBXLink DMI-4 Plus. If only one version of the Connected Systems PBXLink is being referred to, the full name will be used.
There are five types of Connected Systems PBXLinks that can be used with Voice Services, three of which can be used with a Nortel Meridian 1 PBX (see the table below)
PBXLink type                    Compatible PBX
PBXLink                         Lucent Definity
                                                Nortel Meridian 1
PBXLink ISA                     Lucent Definity
                                                Nortel Meridian 1
PBXLink ISA 4x4         Mitel SX-50, SX-200, SX-2000
                                                Nortel Norstar
PBXLink DMI-4           Mitel SX-50
                                                Nortel Norstar
PBXLink DMI-4 Plus      Nortel Meridian 1
                                                Mitel SX-200, SX-2000
Connected Systems PBXLink ISA
The Connected Systems PBXLink ISA is an ISA card installed in the Voice Services machine. Each card can support up to 24 lines. It connects to the PBX by a digital line and to Voice Services by an RS-232 link. On the Connected Systems PBXLink ISA, choose any available COM port (between 1 and 4). Configure the COM port in your Windows ports settings (see Configuring the COM port in Windows NT). Write the COM port number on the worksheet.
The following diagram is a representation of a Voice Services machine configured with 2 Brooktrout cards (PCI version) and 1 Connected Systems PBXLink ISA:
121102_21551_0.png
Connected Systems PBXLink
The Connected Systems PBXLink is an external box connected to the PBX by a digital line and to Voice Services by a serial cable. Each box can support up to 48 lines. Configure any available COM port (between 1 and 4) in the Windows port settings. Write the COM port number on the worksheet.
The Connected Systems PBXLink has a default baud rate of 1200, 7, E, 1. As soon as you attach the Connected Systems PBXLink, change the baud rate to 9600, 8, N, 1 by following the instructions in the Connected Systems documentation. Also set Flow Control to OFF.
The following diagram is a representation of a Voice Services machine configured with 3 Brooktrout cards (PCI version) and an external Connected Systems PBXLink:
121102_21613_1.png
Connected Systems PBXLink DMI-4 Plus
The Connected Systems PBXLink DMI-4 Plus is an external box that provides the same function as the Connected Systems PBXLink, but serves fewer lines and does not require direct analog lines to the Brooktrout card. When  you receive your Connected Systems PBXLink DMI-4, you will need to contact Connected Systems to upgrade the firmware to the DMI-4 Plus level, making it compatible with your PBX software.
Since Voice Services uses SMDI integration, it is necessary to turn off inband tones. This is done via the serial port menus by choosing Advanced > Inband Tones and changing Suppress Tones to ON.
The DMI-4 Plus works with both the ISA and PCI Brooktrout cards. If a Brooktrout ISA card is used, the cables that are shipped with the product are used to connect to the Brooktrout card, as illustrated below:
8202002_44020_1.png
If a Brooktrout PCI card is used, you need a customized cable. Centrinity can supply this cable or one can be made following the diagram below:
8202002_44137_3.png
Use the following connections:
RJ45                    RJ12
Pin 1           Pin4 of RJ12-2
Pin 2           Pin 3 of RJ12-2
Pin 3           Pin 2 of RJ12=1
Pin4            Pin3 of RJ12-1
Pin 5           Pin 4 of RJ12-1
Pin 6           Pin 5 of RJ12-1
Pin 7           Pin 5 of RJ12-2
Pin 8           Pin 2 of RJ12-2
Connected Systems PBXLink DMI-4 and DMI-4 Plus
The Connected Systems PBXLink DMI-4 and DMI-4 Plus are external boxes that provide the same function as the Connected Systems PBXLink ISA 4x4 card.
The DMI-4 supports the Mitel SX-50, while the DMI-4 Plus supports the Mitel SX-200 and SX-2000. To upgrade the Connected Systems PBXLink DMI-4 to a DMI-4 Plus, contact Connected Systems for the correct firmware upgrade to use with your system.
Since Voice Services uses SMDI integration, it is necessary to turn off inband tones. This is done via the serial port menus by choosing Advanced > Inband Tones and changing Suppress Tones to ON.
The DMI-4 and DMI-4 Plus work with both the ISA and PCI Brooktrout cards. If a Brooktrout ISA card is used, the cables that are shipped with the product are used to connect to the Brooktrout card, as illustrated below:
8202002_44020_1.png
If a Brooktrout PCI card is used, you need a customized cable. Centrinity can supply this cable or one can be made following the diagram below:
8202002_44137_3.png
Use the following connections:
RJ45                    RJ12
Pin 1           Pin4 of RJ12-2
Pin 2           Pin 3 of RJ12-2
Pin 3           Pin 2 of RJ12=1
Pin4            Pin3 of RJ12-1
Pin 5           Pin 4 of RJ12-1
Pin 6           Pin 5 of RJ12-1
Pin 7           Pin 5 of RJ12-2
Pin 8           Pin 2 of RJ12-2
Configuring the PBX
Read the Connected Systems documentation and follow all the steps for preparing and programming your Nortel Meridian 1 PBX. This may have to be completed by a technician from your phone system provider.
Note
The following section should be used as a supplement to the Connected Systems documentation, highlighting steps which are unique to Voice Services, or where special attention should be taken to ensure successful configuration.
The hunt chain
It is crucial that the sequence of the analog lines for the Brooktrout’s hunt chain be entered correctly. If the numbers are not entered in the correct sequence, incoming calls will not travel through the hunt chain to an open line and will not be answered or processed by Voice Services.
Note
When installing six Brooktrout cards (24 ports), note that keys 16 - 37 are the first 22 lines in the hunt chain (channels 0 - 21). Channels 22 and 23 must be configured to key 05 and key 06 respectively.
It is imperative that the hunt chain sequence is replicated throughout the Voice Services installation and configuration or the hunt chain will not work and your incoming calls and telephone message retrieval will not process correctly. Ensure the sequence is entered accurately on your worksheet for future reference and troubleshooting.
Other required settings
EFD, Hunt and EHT must all point to the pilot number.
•       EFD is the flexible CFNA (Call Forward No Answer) DN for external calls
•       HUNT is the hunt DN of next station in hunt chain
•       EHT is the external Hunt DN.
LDTA (line disconnect tone allowed) is suggested in the Connected Systems documentation. With Voice Services, this MUST be set. This ensures the line will be freed right away when a call is terminated.
Configuring the COM port in Windows NT
Once the Connected Systems PBXLink has been installed and the COM port selected for the card has been entered on your worksheet, configure the COM port in your Windows NT operating system on the Voice Services machine:
1       Open Ports from the Control Panel.
8202002_44217_4.png
COM1 and COM2 may be preconfigured in your machine.
2       Click Add to add the COM port for the Connected Systems PBXLink.
8202002_44217_4.png
3       Choose the COM port you configured for the Connected Systems PBXLink.
4       Set Base I/O Port Address to the number you entered on your worksheet.
5       Set the IRQ to the number you entered on your worksheet.
6       Click OK to return to the Ports dialog box.
7       Click Settings and choose the options shown on the screen below:
8202002_44217_4.png
8       Click Advanced.
8202002_44217_4.png
9       Ensure:
•       the COM port is correct (from the worksheet as above).
•       The Base I/O Port Address and Interrupt Request Line (IRQ) are set to Default.
•       FIFO Enabled is selected.
10      Click OK and exit, saving all changes.
Configuring the Connected Systems PBXLink settings
Once the Connected Systems PBXLink has been connected, and the COM port has been configured in Windows NT, you have to configure the internal settings for your Connected Systems PBXLink configuration.
Create a HyperTerminal file
Create a HyperTerminal file on the Voice Services machine to initialize the Connected Systems PBXLink.
1       Choose Programs > Accessories > Hyperterminal > HyperTerminal from the Start menu.
2       Enter Connected Systems PBXLink at Enter a name for the new connection.
3       Click OK.
4       Enter the COM port number configured for the Connected Systems PBXLink, configured in NT, and recorded on the worksheet at Connect using.
5       Click OK.
6       Type m and press Enter to access the Connected Systems PBXLink menu.
7       Stop the integration before changing any Connected Systems PBXLink settings:
•       Press 1 for the Configuration menu.
•       Press 1 to stop the integration.
8       Enter the following settings by following the steps in the Connected Systems PBXLink manual:
PBX Type
Meridian 1.
PBX Options
Prime # Enter the pilot number. If you ever change the pilot number, restart the Voice Services machine.
Number of lines licensed
Enter number of lines licensed (4, 8, 12, ... up to 24).
Connect using
COM# (where # is the COM port selected on the Connected Systems PBXLink)
Baud rate
9600
Data Bits
8
Parity
No
Stop Bits
1
9       Set the SMDI options.
Check CPID Length (option 2). This is the local dialing number length. If you live in an area where all local calls are 10 digits, ensure CPID Length is set to 10.
10      Restart the integration.
11      Type q and press Enter to exit.
12      Restart the Voice Services machine.
Troubleshooting the Connected Systems PBXLink
When the computer restarts, check the green light on the Connected Systems PBXLink:
The light is on steady
The connection was successful.
The light is on but blinks off briefly every 2 seconds
The digital line is working correctly but the integration must be restarted.
The light is off
The Connected Systems PBXLink is in boot-loader state or is not working correctly. See the Calista documentation.
The light is flashing slowly
The digital line is active but the PBX is not responding to the Connected Systems PBXLink.
The light is flashing quickly
No signal has been detected from the digital line. Check the physical connections and then check the line.
Installing the Brooktrout card(s)
Insert the Brooktrout card(s) into the slot(s) in the Voice Services machine as explained in the Brooktrout installation manual.
Install the Brooktrout software
1       Download the required Brooktrout software from the Voice Services CD.
There are three folders the Brooktrout driver requires:
•       Install
•       Kernel
•       User.
2       Run Install.exe to install the Brooktrout driver.
3       Enter the number of lines you are installing (4 per card).
Configuring PCI Brooktrout card(s)
1       Enter the following information when prompted:
IRQ                                                                     -1
DMA                                                                     -1
Start faxinit on startup                                yes
Additional parameters required? no
2       Go to Faxinit.
Configuring ISA Brooktrout card(s)
Use defaults unless otherwise specified:
IRQ     
5 (recommended)
Any available number between 1 and 10 can be used. For multi-card installations, use the same IRQ number for all cards. Remember to enter this number on the worksheet for future reference.
Set Base I/O address    
•       For a one-card system, the base I/O address should be 260.
•       For a two-card system, the base I/O addresses should be 260 and 280.
•       For additional cards, see the chart in the Brooktrout manual.
Ensure the Base I/O address is entered on the worksheet.
DMA
1 (recommended)
Kernel buffer size
8092 (default)
Kernel IRZ size
10 (default)
Enable default?
No
Start driver automatically?
Yes (default)
Load faxinit on startup?
Yes
Additiional parameters file
Enter the full path to the address file.
Example: c:\winnt\bfax\address
Address file (ISA card only)
Create the address file:
1       Create a new text (ASCII) file using Notepad.
For a one-card system with a starting I/O of 260, the file will contain one line only:
addrs 264 4
For a two-card system with starting I/Os of 260 and 280, the file will contain two lines:
addrs 264 4
addrs 284 4
2       Save the file with the exact full path you specified above.
3       Open Windows Explorer and delete the .txt extension.
Faxinit
When installation is complete, ensure the following files are in your hard disk in the directory c:\winnt\bfax\:
•       bfax.sys
•       faxinit.exe
•       runfaxin.exe.
After faxinit.exe runs, a log file will be created called faxinit.log. Details about faxinit.log are described in Verify hardware install.
At this point, there should be no lights lit on the Brooktrout cards. Once Voice Services has started and the software configurations have been set by following instructions in the administrator's online help, the lights on the Brooktrout cards should flash randomly.